ADL_ Screen
Manage prints, CFS and external spool from the Creality K1C touchscreen.
Screenshots and videoAt a glance
- Availability
- Free
- Main requirement
- Creality K1C with CFS and original display; CFS firmware 2.3.5.34 indicated by the author as tested.
Get started
Free
DownloadWhat you get
CFS and external spool from the same panel
Check the four CFS slots, materials, colors and remaining meters reported by the system. At startup choose CFS or external spool when the CFS is connected. Automatic loading of the external spool requires the ADL Script macros; external material and color are user-entered data.
Starting the print with the useful options
Select a local or USB G-code and, when the integrations are present, choose disabled, adaptive or full mesh and adaptive purging before starting. It brings the operational choices together on the display; the file must already be prepared with a slicer.
Control of the print and of individual objects
Follow progress, times and temperatures, pause, resume or stop the job. You can exclude a part without canceling the others if the G-code contains labeled objects. Estimates and details depend on the available data.
Inside the software
See what it looks like first.
Explore the available screenshots and videos. Captions accompany images when provided.1 of 38
Screenshot 1
Quick guide from the manual
From the first steps to everyday use.
Choose a topic to read the manual content without leaving this page.Installation
Before you start
Install with the printer idle: no print, heating, homing or calibration in progress.
According to the author, the installation replaces the Creality interface by disabling Monitor, display-server, Creality Cloud, the Creality Print LAN connection and OTA firmware updates. The installer shows a warning and asks for confirmation before applying these changes.
The installation and restore scripts are not included in the available local materials.
Installing from the ADL Script menu
Install and open ADL Script following its documentation. Select:
[Customize & PowerScreen] Menu > 1) Install PowerScreen
Read the warning, confirm and select nightly, the channel indicated by the author.
Installing directly from SSH
Connect to the K1C as root, replacing the placeholder with the actual address:
ssh root@IP_DELLA_TUA_K1C
Download the installer indicated in the README and run it:
wget --no-check-certificate -O /tmp/powerscreen-installer.sh https://raw.githubusercontent.com/AlbertoTrento/ADL-Screen/main/installer.sh
sh /tmp/powerscreen-installer.sh nightly
Cloning the repository is not required according to the author's procedure.
Files and changes documented by the author
The installer downloads powerscreen-k1c.tar.gz from the ADL-Screen Releases and installs the program in /usr/data/powerscreen. The README states that it preserves the original Creality files in /usr/data/powerscreen-backup, configures the service, Klipper modules and macros, registers the update in Moonraker, saves the selected channel and restarts Klipper and the panel.
The internal names powerscreen, powerscreen-k1c.tar.gz and /usr/data/powerscreen remain those used by the existing procedures. The description of the preservation of the original files refers to the documented behaviour of the installer; no copy was created in this editorial run.
Features
Filament loading and change from the touchscreen
Load the external spool, unload the filament, extrude or retract a chosen length and turn off the nozzle. During the pause you can access the manual change. The resume macros provided by the project handle exiting the purge bucket: they must not be replaced with the factory RESUME in that position.
Adjustments during the job
Change Z offset, speed, flow and Pressure Advance and access the movement limits. It is useful for stepping in at the machine without typing every command; operational changes do not automatically amount to permanently saving a profile.
Machine commands within reach
Manage homing, moves by distance, motors, temperatures, fans and LEDs. Chamber control requires the intended macros and flags the effect of turning it off on the timelapse. The controls depend on the items configured in Klipper.
Calibrations and maintenance from the display
View the mesh and manage the profiles, run Input Shaper measurements, belt analysis and PID calibration of nozzle and bed. Compatible sensors, modules and macros are required; saves with SAVE_CONFIG restart Klipper.
Files and reprinting previous jobs
Browse local and USB files, sort and delete multiple files as well, check the last 30 jobs requested from Moonraker and reprint a G-code that is still available. History data depends on the configured service.
Timelapse management
Check the timelapses produced by the dedicated module, copy them to a USB stick or delete them with confirmation. The display does not play video: to watch them you need Fluidd or another device.
Console and custom macros
Send G-code, read the responses and run macros with any parameters. It is useful for operations not collected into a dedicated button; the macros actually available are those of the printer.
Configurable language and connection
Choose Italian, English, German, French or Spanish; manage the Wi-Fi networks and check the system information. Italian is the default and changing language restarts the panel to apply the choice.
Additional tools for prepared installations
The code includes conditional access to Spoolman, TMC adjustments and metrics, power devices and nozzle cleaning. These tools appear or become usable depending on the services, modules and macros detected.
Access to updates
Access the Power Update page; the author's procedure also covers updates from Fluidd via Moonraker. The panel restricts access during printing. Downloads and external procedures are documented by the author and were not carried out in this editorial preparation.
System Requirements
- Creality K1C with CFS and original display; CFS firmware 2.3.5.34 indicated by the author as tested.
- Root access and SSH enabled; IP address and root password for the installation.
- Klipper and Moonraker installed and working.
- ADL Script with Power Macros and Klipper Adaptive Meshing & Purging for the filament flows and the macro-dependent options.
- Network connection and Internet access from the printer for installation and updates.
- Printer idle during the installation.
- Specific services, sensors and modules for the optional features, including timelapse, Spoolman, Input Shaper and TMC tools.
Documentation
Purpose and audience
ADL_Screen replaces the stock display interface of the Creality K1C with a touch panel connected to Klipper and Moonraker. It is designed for those who use the CFS and want to manage spools, files, printing and maintenance directly from the printer, including switching to the external spool.
The practical benefit is bringing together on the display operations that would otherwise require Fluidd or manually sending commands: choosing the filament source, preparing a print, intervening during a pause and accessing the settings. The panel does not prepare 3D models and does not replace the slicer. Physical operations are carried out by Klipper and the installed macros.
Compatibility, requirements and status
Intended configuration
The author states the target is the Creality K1C with CFS, root access and the stock screen; he reports testing with CFS firmware 2.3.5.34. No versions are declared for other printers, Android or Raspberry Pi.
Working Klipper and Moonraker installations are required. To install you need SSH enabled, the printer's IP address, the root password and Internet access from the printer. The panel's functions depend on the devices, modules and commands actually present in the configuration.
The author's README indicates preliminary nightly builds. The v0.37.0 notes included in the materials do not allow that version to be assigned with certainty to the current ADL_Screen build.
Integration with ADL Script
The project requires ADL Script to complete the workflows that call external macros. From its menu install at least:
[Install] Menu > 6) Install Power Macros
[Install] Menu > 8) Install Klipper Adaptive Meshing & Purging
The Load filament button calls _CARICA_BOBINA_ESTERNA TEMP=.... The author's README places the macro in ADL Script's files/kamp/Start_Print.cfg. The same document attributes the loading of the external spool to the initial print flow and the restoration of the CFS at the end of the job to the Power Macros in files/power-config/gcode_macro.cfg.
Without these macros the panel can start, but it cannot complete the operations that require them. The camera commands and various maintenance functions also require specific integrations.
Installation
Before you start
Install with the printer idle: no print, heating, homing or calibration in progress.
According to the author, the installation replaces the Creality interface by disabling Monitor, display-server, Creality Cloud, the Creality Print LAN connection and OTA firmware updates. The installer shows a warning and asks for confirmation before applying these changes.
The installation and restore scripts are not included in the available local materials.
Installing from the ADL Script menu
Install and open ADL Script following its documentation. Select:
[Customize & PowerScreen] Menu > 1) Install PowerScreen
Read the warning, confirm and select nightly, the channel indicated by the author.
Installing directly from SSH
Connect to the K1C as root, replacing the placeholder with the actual address:
ssh root@IP_DELLA_TUA_K1C
Download the installer indicated in the README and run it:
wget --no-check-certificate -O /tmp/powerscreen-installer.sh https://raw.githubusercontent.com/AlbertoTrento/ADL-Screen/main/installer.sh
sh /tmp/powerscreen-installer.sh nightly
Cloning the repository is not required according to the author's procedure.
Files and changes documented by the author
The installer downloads powerscreen-k1c.tar.gz from the ADL-Screen Releases and installs the program in /usr/data/powerscreen. The README states that it preserves the original Creality files in /usr/data/powerscreen-backup, configures the service, Klipper modules and macros, registers the update in Moonraker, saves the selected channel and restarts Klipper and the panel.
The internal names powerscreen, powerscreen-k1c.tar.gz and /usr/data/powerscreen remain those used by the existing procedures. The description of the preservation of the original files refers to the documented behaviour of the installer; no copy was created in this editorial run.
Everyday use
Reading the printer status
The Home screen brings together job status and temperatures. The panel shows the temperature and target of the nozzle and bed and the chamber reading, according to the available sensors. The chamber sensor does not imply the presence of a controllable heater.
During printing, progress, elapsed time, estimated remaining time and other data returned by Klipper or by the file metadata, such as layers and material, are available. Information missing from the file or from the service cannot be derived automatically by the panel.
Selecting and starting a G-code
- Prepare the G-code in the slicer.
- Make it available in the Moonraker storage, for example by uploading it from Fluidd, or on a USB stick recognised and mounted by the printer.
- Open the files page and choose Local or USB. Refresh the list after inserting the stick.
- Select the file, review its available data and press Print.
- In the Start print window, set the available options and confirm Start.
The window offers a disabled, adaptive or full mesh when it detects ADAPTIVE_BED_MESH and FULL_BED_MESH; it offers adaptive purging when it detects ADAPTIVE_PURGE_LINE. The adaptive mesh covers the part area, according to the installed integration. If none of the expected options is available, the code starts the file directly through Moonraker.
Choosing CFS or external spool
When the CFS is detected as connected, the start window offers CFS and External spool. For the external spool, first feed the filament up to the extruder.
The panel sends BOX_ENABLE_CFS_PRINT ENABLE=1 for the CFS or BOX_ENABLE_CFS_PRINT ENABLE=0 for the external spool, then requests the file start. The automatic loading and purging described by the author depend on the ADL Script start flow; they are not performed independently by the panel selector.
Viewing and editing spools
Open the CFS page and select one of the four slots. The detail view shows the available spool information, including material, color and the remaining amount reported by the system. Modifica slot lets you change material and color; Controlla filamenti sends a refresh request to the CFS.
Material recognition also handles codes with the 1 prefix, for example 106003, by looking for a match in the catalog. Availability of the name depends on the material being present in the catalog.
The fifth box, Bobina esterna, lets you save material and color in the panel settings. This information is entered by the user: it is not equivalent to automatic detection or to measuring the remaining amount on the external spool.
Loading and unloading filament
On the Filament page, set temperature, length and speed according to the operation required.
- Carica filamento: calls
_CARICA_BOBINA_ESTERNA TEMP=.... If the axes are not homed, it offers to home before loading. - Togli filamento: waits for the set temperature, switches to relative extrusion, retracts 100 mm at 600 mm/min and turns off the nozzle.
- Carica mm: waits for the temperature and feeds the selected length at the chosen speed.
- Scarica mm: waits for the temperature and retracts the selected length at the chosen speed.
- Spegni ugello: sets the extruder target to zero.
The dedicated manual change command is visible during a pause and calls _PS_MANUAL_CHANGE_PROMPT.
Pausing, resuming and cancelling
Use the print screen controls for pause, resume and cancel. The project documents filament change with M600. In the manual dialog the final commands are PS_RESUME and PS_CANCEL; the status screen uses PS_RESUME_PRINT to resume.
Author's warning: after manual loading the nozzle stays in the purge bucket. The stock RESUME may bring it back to the print diagonally and hit the brush. Use the panel's resume button or PS_RESUME_PRINT, which according to the documented macros first move the nozzle out in a straight line. Do not send a plain RESUME from Fluidd or the console while the nozzle is in the bucket. The actual path is the responsibility of the installed macros.
Excluding an object
Open object exclusion during a job that contains multiple labeled objects, choose the one to exclude and confirm. The panel requires object labels in the G-code: enable them in the slicer. A file without this information does not allow selecting individual parts from the panel.
Adjustments and machine control
Movement, homing and temperatures
The axis controls allow moves by the selected distance, homing and motor disabling. G28 X Y Z, G28 X Y, G28 Z and M84 are available, in addition to relative moves. The emergency stop uses the Moonraker request printer.emergency_stop.
Set the thermal targets from the available heater controls. Sensor-only readings, such as the chamber one in the documented configuration, remain informational.
Fine tuning
The Fine Tune page allows you to change:
- Z offset via
SET_GCODE_OFFSET; - speed percentage via
M220; - flow percentage via
M221; - Pressure Advance via
SET_PRESSURE_ADVANCE.
The Limits page changes the limits exposed by Klipper via SET_VELOCITY_LIMIT, including velocity, acceleration and square corner velocity. These commands change the runtime state; they must not be presented as an automatic permanent save of a profile.
Fans, light and camera
The fan controls adapt to the configured items, using the commands provided for standard, generic, temperature-controlled fans or fans exposed as pins. LEDs are driven via SET_PIN or SET_LED, depending on the configuration.
The camera is turned on and off through external macros. The panel checks the service status and warns that turning the camera off interferes with timelapse photos. The availability of the command is not the same as a video player on the display.
Calibrations and maintenance
Bed mesh
Open Bed Mesh to view the map and the profiles. Start the measurement with the related command; if needed, the panel performs homing first. You can load, save and delete profiles and clear the current mesh.
The commands used include BED_MESH_CALIBRATE, BED_MESH_CLEAR and BED_MESH_PROFILE LOAD=..., SAVE=..., REMOVE=.... The saves and removals provided by the panel include SAVE_CONFIG, with a Klipper restart.
Input Shaper
Open Input Shaper, run the axis measurements and review the available results. The panel uses TEST_RESONANCES AXIS=X NAME=x and TEST_RESONANCES AXIS=Y NAME=y, with processing through the script configured as ps_input_shaper.
Saving uses PS_SAVE_INPUT_SHAPER with the selected frequencies and types, followed by SAVE_CONFIG. The sensor, the measurement configuration and the required integrations are needed: the panel alone does not replace them.
Belt analysis
Belts / Shake lets you start the PS_BELTS_SHAPER_CALIBRATION procedure and excite an axis at a chosen frequency via PS_EXCITATE_AXIS_AT_FREQ FREQUENCY=... AXIS=.... These tools help examine the mechanical behaviour; they do not physically adjust belt tension.
Nozzle and bed PID
Open PID Tune, choose the heater and the target temperature, then confirm. The panel sends PID_CALIBRATE HEATER=extruder TARGET=... or PID_CALIBRATE HEATER=heater_bed TARGET=.... The procedure ends with SAVE_CONFIG and a Klipper restart. It is not available during printing.
Conditional features
Nozzle cleaning, TMC Autotune, TMC metrics and power devices are shown according to the detected macros, modules and services. TMC adjustments require the autotune_tmc integration; the provided saves include SAVE_CONFIG. Not all installations will have the same buttons.
Files, history and timelapse
Managing files
The files page lets you browse between local storage and USB, sort by name or modification date, read the available metadata and delete one or more files with confirmation. The USB view depends on a drive actually being mounted and made accessible to Moonraker.
Reviewing and repeating previous jobs
History requests the last 30 jobs and the history totals from Moonraker. Select a job to read its data and use Print again when the G-code is still available. Resetting the totals does not delete the job list.
Managing videos
Timelapse lists the videos in Moonraker's dedicated storage, with a preview when available. You can copy a video to the USB drive or delete it with confirmation.
The panel does not play videos. Open the file from Fluidd or copy it and watch it on another device. Producing the videos requires the timelapse module and the camera to be configured separately.
Console, macros and integrations
Sending commands and macros
The console accepts G-code commands and shows the responses received. The macro page uses the macros exposed by the printer and lets you fill in the expected parameters. Actions containing SAVE_CONFIG or restarts require confirmation in the panel.
The specific commands used by the start-up flow include:
| Command | Function |
|---|---|
BOX_ENABLE_CFS_PRINT ENABLE=0 / ENABLE=1 | Selects external spool or CFS. |
_BED_MESH_OFF | Disables the mesh choice at start-up according to the installed macros. |
_ADAPTIVE_BED_MESH_ON / _FULL_BED_MESH_ON | Selects adaptive or full mesh. |
_ADAPTIVE_PURGE_LINE_ON / _ADAPTIVE_PURGE_LINE_OFF | Enables or disables the adaptive purge. |
_CARICA_BOBINA_ESTERNA TEMP=... | Starts external loading at the specified temperature. |
_PS_MANUAL_CHANGE_PROMPT | Opens the manual change flow. |
PS_RESUME, PS_CANCEL, PS_RESUME_PRINT | Macro commands to end the manual change or resume the print. |
The table describes the commands called or documented by the project; it does not imply that they are available without installing the related macros.
Spoolman and Wi-Fi
The code includes a Spoolman page that can be used when the service is available through Moonraker. It lets you view and select spools; access from the filament entry also depends on the presence of the CFS.
The Wi-Fi page lets you scan for networks, connect by entering the credentials, select saved networks and forget them. It requires the Wi-Fi service provided by the platform.
Language
Open Settings > Language and choose Italian, English, German, French or Spanish. Italian is the default value. The panel saves the preference and restarts its own interface to apply it; the code does not require restarting Klipper for this choice.
Updating
The author's README indicates Settings > Updates; in the sources the button is named Power Update. The panel contains access to update management and blocks its opening when it detects the machine is busy printing.
Alternatively, the author's instructions indicate Settings > Software Updates in Fluidd, after registering the program in the Moonraker update manager. There is no need to run the installer again according to the documented procedure. The actual availability of releases and external updates has not been verified over the network.
Uninstallation and restore
From the ADL Script menu select:
[Customize & PowerScreen] Menu > 2) Remove PowerScreen
Alternatively, connect via SSH and run the documented procedure:
sh /usr/data/powerscreen/reinstall-creality.sh
The author states that this procedure restores the Creality screen and services. After removal, he recommends restarting the printer. The script is not included in the local materials examined.
Troubleshooting and limitations
A button calls an unknown command
Check your installation's configuration for the presence of the macros required by ADL Script. The panel does not internally implement _CARICA_BOBINA_ESTERNA nor the resume path from the tray.
The CFS or external spool choice does not appear
The selector appears when the CFS reports the expected connection status. The mesh and purge options have separate conditions and depend on their respective configuration items.
Objects, previews or job data are not available
Exclusion requires objects labeled in the slicer. Previews, material, layers and estimates depend on the available metadata. The remaining meters are data reported by the CFS, not independent measurements by the panel.
USB or timelapse show no content
The USB stick must be recognized and mounted by the printer; refresh the list after inserting it. Timelapses require the dedicated module and files already produced. The display is not a video player.
Limits of the editorial review
Credits and licenses
ADL_Screen is a modified version of PowerScreen, created by Boris Fernández (Boris SdK), maintained by Alberto (AlbertoTrento) since November 6, 2026. PowerScreen derives from GuppyScreen by ballaswag.
The code is declared GNU GPL-3.0. The original README refers to LICENSE, which is not present in the available local materials.
The PowerUI theme and graphic work are distributed under Creative Commons Attribution-NonCommercial 4.0 International, as specified in LICENSE-POWERUI.md: attribution to Boris Fernández, a link to the license and an indication of changes are required. Commercial use requires the author's permission. This license covers the PowerUI graphic work and does not replace the code license.
PowerUI is based on shadcn/ui; NOTICE.md also includes credits for GuppyScreen, Lucide, Z-Bolt and LVGL. PowerUI license reference: https://creativecommons.org/licenses/by-nc/4.0/.
Get it ADL_Screen
Free
Manage prints, CFS and external spool from the Creality K1C touchscreen.
DownloadYour browser or Windows may show a warning because the file is new and not yet recognized: choose Keep / Run anyway. The file is safe and published directly by Alberto DevLabs.
Continue from here
More tools and content to explore
Software and resources that share the area or topics of this page.
CFS Plugin
View Creality CFS spools in OrcaSlicer and transfer colors and materials to the project's filaments.
OrcaGen Plugin
Creates filament profiles in OrcaSlicer and, with a valid trial or license, adapts processes to the size of the part.
Creality_Filament_Loader
Adds your filaments to the filament database of Creality K1 and K2 printers, with no SSH and no JSON to edit by hand
OrcaGen
Prepare and compare profiles for OrcaSlicer without retyping filament data by hand